Sign In | Join Free | My burrillandco.com
Home > Portable Energy Meter Test Equipment >

HS3103B Portable Electric Meter Test Equipment Accuracy 0.05% CLASS,Current 5mA~120A,RS232 communication

    Buy cheap HS3103B Portable Electric Meter Test Equipment Accuracy 0.05% CLASS,Current 5mA~120A,RS232 communication from wholesalers
     
    Buy cheap HS3103B Portable Electric Meter Test Equipment Accuracy 0.05% CLASS,Current 5mA~120A,RS232 communication from wholesalers
    • Buy cheap HS3103B Portable Electric Meter Test Equipment Accuracy 0.05% CLASS,Current 5mA~120A,RS232 communication from wholesalers

    HS3103B Portable Electric Meter Test Equipment Accuracy 0.05% CLASS,Current 5mA~120A,RS232 communication

    Ask Lasest Price
    Brand Name : SHENGDI TECHNOLOGY
    Model Number : HS3103B
    Certification : SGS,CNAS
    Price : USD$1~100000/SET
    Payment Terms : TT/LC
    Supply Ability : 100SET/MONTHS
    Delivery Time : 15 days
    • Product Details
    • Company Profile

    HS3103B Portable Electric Meter Test Equipment Accuracy 0.05% CLASS,Current 5mA~120A,RS232 communication

    HS3103 Portable 1 Phase Energy Meter Test Equipment

    Technical specification

    1. Electrical output

    1) Voltage and current measurement range

    Output voltage ranges: 57.7V/63.5V and 220V/240V (480V option)

    Output current ranges: 0.1A, 1A, 5A, 20A, and 100A

    2) Output load capacity

    Voltage loop: Max. 50VA

    Current loop: Max 100VA (Measurement range 100A)


    2. Electrical output adjustment

    1) Voltage adjustment

    a) Adjustment range: 0%~125% selected voltage range

    b) Adjustment fineness: four finenesses as 10%, 1%, 0.1%, and 0.01% are

    available

    c) Max. output voltage: 300V or 600V

    2) Current adjustment

    a) Adjustment range: 0%~120% selected current range

    b) Adjustment fineness: four finenesses as 10%, 1%, 0.1%, and 0.01% are

    available

    c) Max. output current: 120A

    3) Phase adjustment

    a) Adjustment fineness: 0°~359.99°

    b) Adjustment fineness: four finenesses as 10°, 1°, 0.1°, and 0.01° are

    Available


    3. Voltage and current output distortion

    This device’s voltage and current output distortion will not be more than 1%

    (testing under linear load)


    4. Output power stability

    This device’s pre-set output power will not exceed 0.05% compared with the

    measurement range variation within 180S.


    5. Harmonic content

    a) Number of harmonic waves: 2~31

    b) Harmonic content: less than 40% (compared with fundamental wave)

    c) Harmonic phase: 0°~359.99°


    6. Monitoring instrument

    To be read directly from the standard meter.


    7. Electric pulse

    Electric pulse output from standard meter:

    1) For error calculator to calculate the error of any meter to be tested;

    2) For the reference of upper-level measurement examination and

    determination agency when sending the standard meter to them for testing.

    Please refer to standard meter’s Table of Constants for pulse constants.


    8. Power supply

    Single-phase AC 220V/240V (100V/110V/230V is also applicable), 50/60Hz,

    max. input power consumption: 500W.


    Technical Parameters

    Item0.050.1
    AccuracyHS-5100 0.05/
    TC-3000C 0.05(embedded)
    HS-5100 0.1/
    TC-3000C 0.1(embedded)
    Rangevoltage:20~300V current:5mA~120A
    Phase0~360°, resolution:0.01°
    F45~65Hz ,resolution:0.01Hz
    THDvoltage,current<0.5%(linear load)
    Power stability<0.05%/120s<0.1%/120s
    Output contentVoltage:50VA current:100VA(100A)
    Load characteristicresistive,inductive,capacitive(less than 1uF/each station)
    Starting up currentMin.2mA,Accuracy:5%,starting up power: accuracy 5%
    Pulse input≤1kHz
    COM. testRS485/232/IR/carrier,support DL/T645-1997/2007,IEC1107
    Tested meter1~3
    Work conditionsTemp.:20℃±5℃; Humidity:<85% R.H.
    Input powerAC220±10%,50/60Hz,(AC120V optional);Max. consumption:500VA

    Model

    ModelNameApplication
    HS-3103single-phase energy meter portable equipmentcommissioning,maintenance,development
    HS-3103Bsingle-phase energy meter movable equipmentdevelopment,calibration

    Functions

    ItemHS-3103HS-3103B
    Basic
    Functions
    basic error
    creeping test
    starting up test
    standard deviation
    constants test
    dial error
    influence test
    othersdaily timing error ☆
    GPS☆
    COM. test ☆
    • :●─Standard;〇─Selection.
    • means special functions

    Configuration

    ModelHS-3103HS-3103B
    reference standard meter
    signal source
    error process system
    meter rack
    clock tester
    GPS
    optical sampling
    • :●─Standard;〇─Selection